CLMGG - SIGMAFORM HEAT-SHRINKABLE POLYMERIC PRODUCTS

  • MSDS: CLMGG
  • Manufacturer: RAYCHEM CORP
  • Product Name: SIGMAFORM HEAT-SHRINKABLE POLYMERIC PRODUCTS
  • National Stock Number: 5330-01-377-5321
Product Identification

Product ID:SIGMAFORM HEAT-SHRINKABLE POLYMERIC PRODUCTS
MSDS Date:11/01/1994
FSC:5330
NIIN:01-377-5321
Status Code:A
MSDS Number: CLMGG

Responsible Party
RAYCHEM CORP
300 CONSTITUTION DRIVE
MENLO PARK, CA 94025
US

Emergency Phone: (800)424-9300

Info Phone: 650-361-4907

Preparer: DONNA SEID

Cage: FO008

Contractor
SIGMAFORM CORP
RICHBORO, PA 18954-0515 US

Telephone: 215-322-4453

Cage: 50015

Ingredients

HEAT-SHRINKABLE POLYMERIC PRODUCTS ARE NOT HAZARDOUS DURING

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE CONTACT: MOLTEN MATERIAL
MAY CAUSE THERMAL BURNS. SKIN CONTACT: PRODUCT IS NOT EXPECTED TO
BE A SKIN IRRITANT. MOLTEN MATERIAL MAY CAUSE THERMAL BURNS. NO
HARMFUL EFFECTS ARE EXPECTED FROM SKIN ABSORPTION OF THIS PRODUCT.
INGESTION (SWALLOWING): INGESTION IS HIGHLY UNLIKELY. THERE IS
INSUFFICIENT INFORMATION AVAILABLE TO PREDICT THE EFFECTS FROM
INGESTION. INHALATION (BREATHING): IN CO MMON WITH MOST ORGANIC
MATERIALS, THERMAL DEGRADATION AND COMBUSTION BYPRODUCTS MAY BE
TOXIC AND SHOULD NOT BE INHALED. COMMENT:OVERHEATING PRODUCT TO
CHARRING OR BURNING MAY PRODUCE VAPORS THAT MAY C AUSEEYE, NOSE,
AND THROAT IRRITATION.
Explanation of Carcinogenicity:NONE OF THE INGREDIENTS TO WHICH USERS
MAY BE EXPOSED AND WHICH ARE PRESENT AT EQUAL TO OR GREATER THAN
0.1% OF THE PRODUCT, ARE LISTED BY OSHA, NTP, OR IARC AS SUSPECT
CARCINOGENS.
Effects of Overexposure:EYE CONTACT: MOLTEN MATERIAL MAY CAUSE THERMAL
BURNS. SKIN CONTACT: MOLTEN MATERIAL MAY CAUSE THERMAL BURNS.
INGESTION: NONE. INHALATION: COMBUSTION PRODUCTS MAY BE TOXIC.
OVERHEATING THE PRODUCTTO CH ARING OR BURNING: VAPORSMAY CAUSE EYE
SKIN, NOSE AND THROAT IRRITATION.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING EYE,
SKIN, OR RESPIRATORY DISORDERS ( ASTHMA CONDITIONS) MAY BE MORE
SUSCEPTIBLE TO THE VAPORS GENERATED FROM OVERHEATING TO CHARRING OR
BURNING OF THIS PRODUCT.

First Aid

First Aid:EYES: IF IRRITATION OCCURS, HOLD EYELIDS APART AND FLUSH
WITH WATER. SEEK MEDICAL ATTENTION. SKIN: FIRST AID NOT NORMALLY
REQUIRED. AFTER HANDLING PRODUCT WASH HANDS. IF MOLTEN MATERIAL
CONTACTS SKI N, COOL AREA IN WATER. DO NOT REMOVE MATERIAL FROM
SKIN. TREAT AS A BURN, SEEK MEDICAL ATTENTION. INGESTION: SEEK
MEDICAL ATTENTION. INHALATION: MOVE TO FRESH AIR. IF SYMPTOMS
PERSIST, SEEK MEDICAL ATTENTION. IF BREATHING DIFFICULT, GIVE
OXYGEN BY QUALIFIED PERSONNEL. IF NOT BREATHING GIVE ARTIFICIAL
RESPIRATION. SEEK MEDICAL ATTENTION.

Fire Fighting

Lower Limits:NOT APPLICAB
Upper Limits:NOT APPLICAB
Extinguishing Media:CARBON DIOXIDE, WATER, DRY CHEMICAL, FOAM,
Fire Fighting Procedures:FIREFIGHTERS SHOULD WEAR SELF CONTAINED
BREATHING APPARATUS WITH A FULL FACEPIECE OPERATED IN THE POSITIVE
DEMAND MODE WHEN FIGHTING FIRES.
Unusual Fire/Explosion Hazard:TOXIC FUMES MAY BE GIVEN OFF IN A FIRE.
SEE ALSO STORAGE, HANDLING, AND OTHER PRECAUTIONS.

Accidental Release

Spill Release Procedures:SWEEP UP AND COLLECT IN SUITABLE CONTAINER FOR
DISPOSAL OR REUSE.

Handling

Handling and Storage Precautions:HANDLING: FOR PRODUCTS CONTAINING A
THERMOCHROMIC TEMPERATURE INDICATOR, DISCONTINUE HEATING AFTER
COLOR CHANGES FROM RED TO COLORLESS. AVOID VAPORS GIVEN OFF IF
PRODUCT IS HEATED TO DECOMPOSITION, AS SHOWN BY A DARKENING AND
BROWNING OF THE SLEEVE. AVOID CONTACT (CONTD. SEE "OTHER
PRECAUTIONS")
Other Precautions:(CONTD. FROM "HANDLING") WITH MOLTEN MATERIAL.
HEAT-RESISTANT GLOVES ARE REQUIRED IF HOT PRODUCTS ARE HANDLED
AFTER INSTALLATION. DO NOT CONSUME FOOD, BEVERAGES OR TOBACCO IN
THE IMMEDIATE WORK AREA. WASH HANDS BEFORE EATING, DRINKING, OR
SMOKING. OTHER PRECAUTIONS: AVOID HEATING PRODUCTS (CONTD. SE E
"TOXICOLOGICAL")

Exposure Controls

Respiratory Protection:IF INSTALLATION OCCURS IN A CONFINED,
UNVENTILATED AREA, NIOSH/MSHA-APPROVED RESPIRATORS ARE RECOMMENDED.
Ventilation:IN ACCORDANCE WITH GOOD INDUSTRIAL HYGIENE PRACTICE, ENSURE
ADEQUATE VENTILATION DURING INSTALLATION.
Protective Gloves:HEAT RESISTANT GLOVES IF DANGER OFCONTACTING MOLTEN
MATERIAL.(CONTD.SEE SUPPL.)
Eye Protection:EYE / FACE PROTECTION; FOLLOW OSHA, ANSI, OR NIOSH
GUIDELINES.
Other Protective Equipment:IF IT IS NECESSARY TO HANDLE GROSSLY
OVERHEADED OR FIRE-DAMAGED PRODUCTS, WEAR NATURAL RUBBER GLOVES TO
PREVENT POSSIBLE CONTACT WITH POTENTIALLY CORROSIVE INORGANIC ACID
RESIDUES.
Work Hygienic Practices:AVOID CONTACT WITH MOLTEN MATERIAL. DO NOT
CONSUME FOOD, BEVERAGES, OR TOBACCO IN IMMEDIATE WORK AREA. WASH
HANDS BEFORE EATING, DRINKING, OR SMOKING.
Supplemental Safety and Health
(CONTD, FROM "GLOVES") WEAR NATURAL RUBBER GLOVES TO PREVENT CONTACT
WITH POTENTIALLY CORROSIVE INORGANIC ACID RESIDUES.

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:NOT PROVIDED BY MFR
Decomp Temp:Decomp Text:NOT PROVIDED BY MFR
Vapor Density:NOT APPLIC
Spec Gravity:1.2 - 2.0 G/CC (WATER=1)
pH:NOT PROVIDED
Viscosity:NOT PROVIDED BY MFR
Solubility in Water:INSOLUBLE
Appearance and Odor:PLASTIC TUBING AND MOLDED PARTS IN VARIETY OF
SHAPES, SIZES , COLORS, NO ODOR.
Percent Volatiles by Volume:NOT APPLICAB
Corrosion Rate:NOT PROVIDED BY MFR

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:AVOID OVERHEATING OF PRODUCT. THIS PRODUCT
IS STABLE UNDER NORMAL CONDITIONS.
Hazardous Decomposition Products:AT TEMPERATURES HIGHER THAN
RECOMMENDED FOR PROPER INSTALLATION, MOST SIGNIFICANTLY IF PRODUCT
BURNS, THERMAL DEGRADATION AND COMBUSTION BYPRODUCTS WILL DEPEND ON
BASE (CONTD. SEE "TOXICOLOGICAL")
Conditions to Avoid Polymerization:WILL NOT OCCUR. NOKNOWN
POLYMERIZATION CONDITIONS TO AVOID.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL LOCAL, STATE, AND
FEDERAL REGULATIONS. IF THERE ARE LOCAL REGULATIONS COVERING THE
CONTROLLED INCINERATION OF HALOGENATED MATERIALS, THEN ALL
HALOGEN-CONTAINING PRODUCTS WILL BE SUBJECT TO SUCH REGULATIONS.
REFER TO PRODUCT LITERATURE FOR IDENTIFICATION OF HALOGEN-CON
TAINING PRODUCTS.

Toxicology

Toxicological Information:(CONTD. FROM "OTHER PRECAUTIONS") BEYOND
TEMPERATURES REQUIRED FOR NORMAL INSTALLATION. SEE INSTALLATION
INSTRUCTIONS FOR PROPER INSTALLATION PROCEDURES. IF PRODUCT CHARS
OR BURNS, IMMEDIATELY STOP HE ATING. AVOID INHALING ANY FUMES WHICH
MAY BE GIVEN OFF. ALLOW VAPORS TO DISPERSE AND VENTILATE BEFORE
CONTINUING WORK IN THE AREA. (CONTD. FROM "HAZARDOUS DECOMPOSITION
PRODUCTS") POLYMER USED, AND MA Y INCLUDE, BUT ARE NOT LIMITED TO,
CARBON MONOXIDE, CARBON DIOXIDE, ALDEHYDES, ACETIC ACID, LOW
MOLECULAR WEIGHT HYDROCARBONS, SILICON DIOXIDE, HYDROGEN CHLORIDE,
HYDROGEN FLUORIDE, FLUORO-0LEFINS, AN D OXIDES (CONTD. SEE
"ECOLOGICAL")

Ecology

Ecological:(CONTD. FROM "TOXICOLOGICAL") OF NITROGEN, PHOSPHORUS AND
SULFUR. THESE COMBUSTION BYPRODUCTS MAY BE TOXIC AND SHOULD NOT BE
INHALED. INSTALLATION: FOLLOW APPROPRIATE SIGMAFORM INSTALLATION
INSTRUCTIO NS AND APPLICATION GUIDES TO ENSURE THAT INSTALLATION IS
PERFORMED PROPERLY. ENSURE THAT ANY LOCAL REQUIREMENTS /
LEGISLATION CONCERNING THE USE OF HAND-HELD ELECTRICAL EQUIPMENT
ARE OBSERVED. WHEN US ING IR (INFRARED) HEATING DEVICES, OBSERVE
SPECIFIC INSTRUCTIONS. DO NOT TOUCH HOT SURFACES ON INSTALLATION
EQUIPMENT.

Transport

Transport Information:THESE PRODUCTS ARE NON-HAZARDOUS UNDER DEPARTMENT
OF TRANSPORTATION REGULATIONS 49 CFR SECTION 171.8, IATA, IMO, AND
AFR 71-4. BECAUSE THERE ARE NO APPLICABLE SHIPING REGULATIONS FOR
THESE PRODUCTS, L ABELS ARE NOT REQUIRED ON THE OUTSIDE SHIPPING
CONTAINER FOR THESE PRODUCTS AND ALL PRODUCTS MAY BE SHIPPED
THROUGH THE U.S. POSTAL SERVICES. DOT, PSN: NOT REGULATED; ID: NOT
REGULATED; DOT HAZARD CLA SS: NOT REGULATED; .

Regulatory

Federal Regulatory Information:TSCA INVENTORY STATUS: ALL INGREDIENTS
ARE LISTED.
State Regulatory Information:

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.